| ELECTRICAL |
| ALARM SENSE |
OPEN connection for alarm
SHORT for normal (non-alarm state) |
| ALARM TYPE |
TX and RX independent |
| RESPONSE TIME |
< 1 Second |
| TX MUTE |
Active during a TX switch (0.5 seconds) |
| TX IF IMPEDANCE |
50 ohms (75 ohms optional); type N |
| TX IF LEVEL |
±20 dBm MAX |
| TX IF INSERTION LOSS |
3.5 dB typ. |
| RX IF IMPEDANCE |
50 ohms (75 ohms optional); type N |
| RX IF INSERTION LOSS |
0.5 dB MAX |
| TX RF INSERTION LOSS |
0.02 dB MAX (switch only) |
| TX RF VSWR |
<1.05:1 MAX (switch only); WR-137
or WR-75 |
| RX RF INSERTION LOSS |
0.02 dB MAX (switch only) |
| RX RF VSWR |
<1.05:1 MAX (switch only); WR-229
or WR-75 |
|
| SYSTEM |
| MANUAL OPERATION |
Five push-button switches |
| SERIAL PORT |
1 RS-232 or 1 RS-485 |
| PROTOCOL |
RS-232 port supports any "dumb
terminal"
RS-485 port supports addressed packetized data per
AnaCom SMS software specifications |
| ALARM RELAY |
FORM C summary switch alarm; isolated |
| VISUAL INDICATORS |
GREEN LEDs indicate switch position
RED LEDs indicate active alarms |
| POWER |
NONE (+12 volts @ 1 amp derived from
transceivers) |
MECHANICAL
- C-BAND INCLUDES
- Ku-BAND INCLUDES TWO |
Switch Controller box
WR-137 and WR-229 waveguide switches
WR-75 waveguide switches |
|
| ENVIRONMENTAL |
| TEMPERATURE |
-40 to +50°C operational
-60 to +75°C storage |
| ALTITUDE |
15,000 ft (5,000 meters) MAX |
| RAIN |
20 inches per hour |
| WIND |
150 miles per hour |
| VIBRATION |
1.0 g random operational, 2.5 g random
survival |
| SHOCK |
10 g operational, 40 g survival |
|
| POWER & DIMENSIONS |
| CONTROLLER BOX -SIZE / WEIGHT |
8.5" x 9.5" x 4.0" (216 x 241 x 102 mm) / 3 lbs (1.36 kg)
Mounting: 1/2" holes spaced 5" apart each end |
| WR-75 SWITCH - SIZE / WEIGHT |
4.5" x 2.1" x 2.1" (114 x 53 x 53 mm) / 1.5 lbs.(.68 kg.) |
| WR-137 SWITCH - SIZE / WEIGHT |
5.2" x 2.3" x 2.3" (132 x 58 x 58 mm) / 2.5 lbs.(1.14 kg.) |
| WR-229 SWITCH - SIZE / WEIGHT |
8.2" x 3.5" x 3.5" (208 x 89 x 89 mm) / 6.0 lbs.(2.73 kg.) |