Products

KU band
AnaCom's series of SEKU Band VSAT transceivers are available in transmitter output levels of 0 dBm, 2, 4, 8, 16, 20, 25, 40, 50, 60, 80, 100 and 125 Watts, in single or redundant configurations. Higher powers are available with external HPAs. These transceivers are ruggedly built for continuous outdoor duty in all types of environments. They are especially suitable for SCPC, MCPC, and DAMA applications.

Features
text bulletEasy to install.
text bulletNo indoor equipment required.
text bulletBuilt in test facilities for improved maintainability and reduced dependence on external equipment.
text bulletCompliant with INTELSAT and Eutelsat specifications.
text bulletFrequency agile radio equipment. Completely independent TX and RX frequency selection.
text bulletSuperior phase noise, IESS 308 /309.
text bulletAuto ranging power supply.
text bulletOne LNC covers the entire RX Band.
text bulletCE certified.

Flexible Applications
text bulletRural Telecommunications Expansion
text bulletIndustrial Networking
text bulletLAN and WAN extensions
text bulletEmergency link restoration
text bulletRemote Surveillance
text bulletBroadcast
text bulletData distribution and collection
text bulletPoint-of-Sales Systems
text bulletVideo teleconferencing
text bulletConventional Voice Traffic

Compact, Functional Design
AnaCom's
SEKU Band VSAT transceivers integrate all necessary functions into a small, highly integrated out-door package which provides excellent reliability in a wide range of environments and functions.

anacom bug AnaCom, Inc.

SEKu-BAND VSAT TRANSCEIVER SERIES
0 dBm, 2, 4, 8, 16, 20, 25, 40, 50, 60, 80, 100 and 125 Watts

The up converter, down converter, power amplifier, monitor and control and power supply are included in a single enclosure. The only cabling required to the indoor equipment are IF cables. The LNC connects to the transceiver with a single coaxial cable.

An ovenized, high stability crystal oscillator is used to lock the TX and RX synthesizers. The onboard microprocessor is used to give additional temperature and aging compensation.

BITE Facility
To improve and simplify maintenance routines, an external terminal (or computer) can be connected to monitor a number of critical parameters without use of additional test equipment. These include:
text bulletTransmitter power output
text bulletPower supply voltages
text bulletTX and RX local oscillator stresses
text bulletInternal temperature
text bulletAlarm details

Controllable functions from the terminal include:
text bulletTX frequency
text bulletRX frequency (independent from TX)
text bulletTX gain (including OFF / ON)
text bulletRX gain
text bulletRF gain

Comprehensive Monitor & Control
A powerful Monitor and Control feature allows you to monitor and control the transceiver on the same M&C bus with most indoor equipment such as modems and multiplexers. The Monitor & Control system can be used in combination with the unit's internal metering function to monitor operational parameters.

MS DOS and Windows®-based Supervisor M & C software is provided for use in combination with a PC for monitoring and controlling all major earth station equipment besides the transceiver.


Benefits
text bulletA family of products with significant commonality minimizes demands for spares and training.
text bullet"Last Touch" controls allow for remote configuration or local (manual) configuration.
text bulletFlash memory means that the transceiver always powers up with exactly the same operating conditions as when it lost power (or was turned off).
text bulletComprehensive maintenance features for operational effectiveness and minimum outages.
text bulletSimple installation.
text bulletManufactured using state-of-the-art technology.

------------------------------
Additional Information

AnaSat SEKu Specifications (HTML format)

PDF icon 0dBm to 4W Datasheet
(PDF: 337 KB)

PDF icon 8W to 25W Datasheet
(PDF: 362 KB)

PDF icon 40W and 50W Datasheet
(PDF: 365 KB)

PDF icon 80W, 100W, and 125W Datasheet
(57 KB)

Diagrams: Super Extended Ku-Band Transceivers

PDF icon0dBm Ku-Band & Extended Ku-Band Transceiver
(PDF: 54 KB)

PDF icon2/4 WATT Ku-Band & Extended Ku-Band Transceivers
(PDF: 54 KB)

PDF icon8 WATT Ku-Band & Extended Ku-Band Transceivers
(PDF: 54 KB)

PDF icon16/20/25 WATT Ku-Band & Extended Ku-Band Transceivers
(PDF: 54 KB)

PDF icon 40/50/60 WATT Ku-Band & Extended Ku-Band Transceivers
(PDF: 62 KB)

PDF icon Ku-Band 80/100/125 WATT Transceiver, Single Enclosure!
(135 KB)

Operation Manuals

PDF icon Anasat Ku-band Operations Manual
(PDF: 3.8 MBytes)

 

-------------------
Get Acrobat Reader If you experience difficulty reading PDF files, please download the most recent version of Acrobat Reader

 

About AnaCom | Sales | Service | News | Job Opportunities | Products | Docs

---------------------------------------
© 2000, 2002, 2003, 2004, 2005 AnaCom, Inc. All Rights Reserved.